Delayed Coker Foam Control

Foam in delayed coker units can cause significant difficulties resulting in throughput restrictions, off-specification products, and in cases of foam carry-over, the possibility of significant fouling. Foam exists in coke drums as the hot vapors of the disengaging gasses separate from the pitch in the coke drum. Nalco Water has developed products and application strategies to reduce foaming and its impacts.

Delayed Coker Foam Control

A well-designed and operated antifoam program can be used to increase coker throughput and minimize transfer line and fractionator fouling with coke fines. Most importantly, it can reduce the possibility of costly foam-overs. Foaming in the delayed coker unit occurs in the coke drum. As the coke drum begins to fill up with solid coke, the liquid level and the foaming head are pushed up. If left unchecked, the foam will reach near the top of the coke drum and potentially exit the drum, or “foam-over”.

In the case of a foam-over, hydrocarbon is carried overhead and fouls the transfer line from the coke drum to the fractionation tower, and the suction screens of the bottom of the tower become plugged. The finer particles of coke that pass through the suction screens will deposit in the furnace heater tubes and result in severe fouling.  The foam-over event could also lead to more silica downstream, potentially poisoning HDS catalyst. Therefore, proper application of the antifoam is critical.

Another important aspect of the antifoam application is the amount of space remaining between the top of the coke bed and the top of the drum at the end of the cycle. This distance is called the outage. By minimizing the outage in each drum, higher throughput to the coker can be maintained.

Nalco Water has a selection of antifoams that are applied in order to control the foam front in the coke drum. These antifoams are specialized in optimizing performance relative to the coker and quality of the coker products.

Refinery Crude Unit on left_Crop_550x310.jpg

Case Study

Low Silicon Antifoam Improves Efficacy and Reduces Silicon Carryover

Programs, Products, Equipment and Services 

Explore Our Delayed Coker Foam Control Offerings

Get In Touch with Us

Give Us a Call

With unparalleled expertise and cutting-edge technology, we partner with customers to deliver world-class results and optimized operations. Contact us to learn how we can help you.

Nalco Water 
1601 W. Diehl Road
Naperville, Il 60563

Thank you for your interest in our chemical processing industry products and services.

Nalco Water Customer Service: +1-800-288-0879